      <title>압축 공기 시스템 Compressed air systems.</title>
      <link>https://jacksonrius.tistory.com/17</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock widthContent&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;646&quot; data-origin-height=&quot;245&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/WxtkW/btstbdrv7eA/v0ylA474CHkzAjDTc7BeX0/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/WxtkW/btstbdrv7eA/v0ylA474CHkzAjDTc7BeX0/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/WxtkW/btstbdrv7eA/v0ylA474CHkzAjDTc7BeX0/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FWxtkW%2Fbtstbdrv7eA%2Fv0ylA474CHkzAjDTc7BeX0%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;646&quot; height=&quot;245&quot; data-origin-width=&quot;646&quot; data-origin-height=&quot;245&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;blockquote data-ke-style=&quot;style1&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;Compressed air systems are widely used in various industries for powering tools, equipment, and processes. These systems involve the generation, treatment, distribution, and utilization of compressed air. Here's an overview of the components and aspects of compressed air systems:&lt;br /&gt;&lt;br /&gt;압축 공기 시스템은 도구, 장비 및 프로세스에 전력을 공급하기 위해 다양한 산업에서 널리 사용됩니다. 이러한 시스템에는 압축 공기의 생성, 처리, 분배 및 활용이 포함됩니다. 압축 공기 시스템의 구성 요소와 측면에 대한 개요는 다음과 같습니다.&lt;/span&gt;&lt;/span&gt;&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style4&quot; /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;/span&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt;&lt;/span&gt;&lt;/blockquote&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;1. Air Compressor:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt; An air compressor is a mechanical device that converts power, typically from an electric motor or an internal combustion engine, into potential energy stored in compressed air. It takes in atmospheric air and compresses it to a higher pressure, resulting in a smaller volume of air. This compressed air can then be used for various tasks, such as operating pneumatic tools, inflating tires, painting, and more. Air compressors come in various types, including reciprocating (piston), rotary screw, and centrifugal compressors, each with its own advantages and applications.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt;&lt;b&gt;공기 압축기:&lt;/b&gt; 공기 압축기는 일반적으로 전기 모터 또는 내연 기관의 동력을 압축 공기에 저장된 위치 에너지로 변환하는 기계 장치입니다. 대기 공기를 흡입하여 더 높은 압력으로 압축하여 공기의 양을 줄입니다. 이 압축 공기는 공압 공구 작동, 타이어 팽창, 페인팅 등과 같은 다양한 작업에 사용될 수 있습니다. 공기 압축기에는 왕복동(피스톤), 회전식 스크류, 원심 압축기 등 다양한 유형이 있으며 각각 고유한 장점과 용도가 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Reciprocating (Piston) Compressors:&lt;/b&gt; They use a &lt;b&gt;piston&lt;/b&gt; to compress air in a cylinder. They are suitable for small to medium applications.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;왕복동(피스톤) 압축기:&lt;/b&gt; &lt;b&gt;피스톤&lt;/b&gt;을 사용하여 실린더의 공기를 압축합니다. 이는 중소형 애플리케이션에 적합합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Rotary Screw Compressors:&lt;/b&gt; These use &lt;b&gt;helical screws&lt;/b&gt; to compress air. They are more efficient and are often used in industrial applications.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;회전식 스크류 압축기:&lt;/b&gt; &lt;b&gt;나선형 스크류&lt;/b&gt;를 사용하여 공기를 압축합니다. 이는 더 효율적이며 산업 응용 분야에서 자주 사용됩니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Centrifugal Compressors:&lt;/b&gt; These are used for large-scale applications and rely on &lt;b&gt;centrifugal force&lt;/b&gt; to compress air.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;원심 압축기:&lt;/b&gt; 이는 대규모 응용 분야에 사용되며 &lt;b&gt;원심력&lt;/b&gt;에 의존하여 공기를 압축합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;2. Receiver Tank:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt; A receiver tank, also known as an air tank or air receiver, is a storage vessel used to store compressed air after it leaves the compressor but before it is distributed to various points of use. The tank serves several important functions:&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;리시버 탱크:&lt;/b&gt; 에어 탱크 또는 에어 리시버라고도 알려진 리시버 탱크는 압축 공기가 압축기를 떠난 후 다양한 사용 지점으로 분배되기 전에 압축 공기를 저장하는 데 사용되는 저장 용기입니다. 탱크는 몇 가지 중요한 기능을 수행합니다.&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Air Storage: It provides a reservoir of compressed air that can be drawn upon during periods of high demand, &lt;b&gt;ensuring a consistent supply of air&lt;/b&gt; even if the compressor output varies.&lt;/li&gt;
&lt;li&gt;공기 저장: 수요가 많은 기간 동안 흡입할 수 있는 압축 공기 저장고를 제공하여 압축기 출력이 변하더라도 &lt;b&gt;일관된 공기 공급을 보장&lt;/b&gt;합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Pressure Stabilization: The tank helps to &lt;b&gt;stabilize air pressure fluctuations&lt;/b&gt; caused by the intermittent operation of the compressor.&lt;/li&gt;
&lt;li&gt;압력 안정화: 탱크는 압축기의 간헐적인 작동으로 인해 발생하는 &lt;b&gt;공기 압력 변동을 안정화&lt;/b&gt;하는 데 도움이 됩니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Condensate Removal: As compressed air cools, moisture in the air can condense into liquid water. The receiver tank often has a drain at the bottom to &lt;b&gt;remove this condensed water&lt;/b&gt;, preventing it from reaching downstream equipment where it could cause damage or affect performance.&lt;/li&gt;
&lt;li&gt;응축수 제거: 압축 공기가 냉각되면 공기 중의 수분이 액체 물로 응축될 수 있습니다. 리시버 탱크에는 종종 &lt;b&gt;응축수를 제거&lt;/b&gt;하기 위한 배수구가 바닥에 있어 손상을 유발하거나 성능에 영향을 줄 수 있는 다운스트림 장비에 도달하는 것을 방지합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;3. Dryer:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt; An air dryer is a device used to &lt;b&gt;remove moisture (water vapor) from compressed air&lt;/b&gt;, enhancing its quality and preventing potential issues caused by moisture in pneumatic systems. Moisture in compressed air can lead to corrosion, damage to equipment, and compromised performance. There are several types of air dryers, including:&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;드라이어(Dryer):&lt;/b&gt; 에어 드라이어는 &lt;b&gt;압축공기 중의 수분(수증기)을 제거&lt;/b&gt;하여 압축공기의 품질을 향상시키고, 공압시스템의 수분으로 인해 발생할 수 있는 문제를 예방하는 데 사용되는 장치입니다. 압축 공기에 수분이 있으면 부식, 장비 손상 및 성능 저하가 발생할 수 있습니다. 공기 건조기에는 다음과 같은 여러 유형이 있습니다.&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Refrigerated Dryers&lt;/b&gt;: These work by cooling the compressed air to a temperature where water vapour condenses, allowing it to be separated and drained.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;냉동식 건조기&lt;/b&gt;: 압축 공기를 수증기가 응축되는 온도까지 냉각하여 분리 및 배수할 수 있도록 하는 방식으로 작동합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Desiccant Dryers:&lt;/b&gt; These use adsorption or absorption methods to remove moisture from the air. They use materials called desiccants that have a high affinity for water vapour.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;건조제 건조기:&lt;/b&gt; 흡착 또는 흡수 방법을 사용하여 공기에서 수분을 제거합니다. 그들은 수증기에 대한 친화력이 높은 건조제라는 재료를 사용합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Membrane Dryers:&lt;/b&gt; These use semi-permeable membranes to separate water vapour from the compressed air stream.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;멤브레인 건조기:&lt;/b&gt; 반투과성 멤브레인을 사용하여 압축 공기 흐름에서 수증기를 분리합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Heat-of-compression (HOC) Dryers:&lt;/b&gt; These utilize the heat generated during the compression process to remove moisture from the air.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;압축열(HOC) 건조기:&lt;/b&gt; 압축 과정에서 발생하는 열을 활용하여 공기에서 수분을 제거합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;4. Air Filters:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt; Air filters &lt;b&gt;remove contaminants&lt;/b&gt;, such as dust, oil, and particulates, from the compressed air. They protect downstream equipment and ensure the air quality meets specific requirements.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;공기 필터:&lt;/b&gt; 공기 필터는 압축 공기에서 먼지, 오일, 미립자와 같은 &lt;b&gt;오염 물질을 제거&lt;/b&gt;합니다. 이는 다운스트림 장비를 보호하고 공기 품질이 특정 요구 사항을 충족하도록 보장합니다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;5. Air Utilization:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Point-of-Use Applications:&lt;/b&gt; Compressed air is utilized for various applications, including:
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Pneumatic Tools:&lt;/b&gt; Such as drills, impact wrenches, and sanders.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Automation:&lt;/b&gt; Controlling pneumatic cylinders, actuators, and valves &lt;i&gt;&lt;b&gt;in manufacturing processes&lt;/b&gt;.&lt;/i&gt;&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Spray Painting:&lt;/b&gt; Compressed air is used to atomize paint for even application.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Packaging:&lt;/b&gt; Powering machines that seal, label, and package products.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;5. 공기 이용:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;사용 시점 응용 분야:&lt;/b&gt; 압축 공기는 다음을 포함한 다양한 응용 분야에 활용됩니다.
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;공압 도구:&lt;/b&gt; 드릴, 임팩트 렌치, 샌더 등.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;자동화:&lt;/b&gt; 제조 공정에서 공압 실린더, 액추에이터 및 밸브를 제어합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;스프레이 페인팅:&lt;/b&gt; 균일한 도포를 위해 압축 공기를 사용하여 페인트를 분무합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;포장:&lt;/b&gt; 제품을 밀봉하고 라벨을 붙이고 포장하는 기계에 전원을 공급합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;6. Energy Efficiency:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Efficiency Considerations:&lt;/b&gt; Compressed air systems can be energy-intensive. Ensuring proper system design, regular maintenance, leak detection, and using energy-efficient components can significantly reduce energy consumption and operational costs.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;6. 에너지 효율성:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;효율성 고려 사항:&lt;/b&gt; 압축 공기 시스템은 에너지 집약적일 수 있습니다. 적절한 시스템 설계, 정기적인 유지 관리, 누출 감지 및 에너지 효율적인 구성 요소 사용을 보장하면 에너지 소비와 운영 비용을 크게 줄일 수 있습니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;7. Maintenance and Monitoring:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;Regular Maintenance:&lt;/b&gt; Routine maintenance of compressors, dryers, filters, and distribution systems is essential to ensure &lt;b&gt;&lt;i&gt;optimal performance and longevity.&lt;/i&gt;&lt;/b&gt;&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Monitoring Systems:&lt;/b&gt; Advanced monitoring systems can help identify inefficiencies, leaks, and issues early, allowing for proactive maintenance.&lt;/li&gt;
&lt;/ul&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;7. 유지 관리 및 모니터링:&lt;/b&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;&lt;b&gt;정기적인 유지 관리:&lt;/b&gt; 압축기, 건조기, 필터 및 분배 시스템의 정기적인 유지 관리는 최적의 &lt;b&gt;성능과 수명&lt;/b&gt;을 보장하는 데 필수적입니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;모니터링 시스템:&lt;/b&gt; 고급 모니터링 시스템은 비효율성, 누출 및 문제를 조기에 식별하여 사전 예방적인 유지 관리를 가능하게 합니다.&lt;/li&gt;
&lt;/ul&gt;
&lt;blockquote data-ke-style=&quot;style3&quot;&gt;In summary, &lt;u&gt;an air compressor compresses atmospheric air to generate compressed air stored in a receiver tank.&lt;/u&gt; &lt;u&gt;A dryer is used to remove moisture from the compressed air&lt;/u&gt;, ensuring its quality and preventing potential issues in downstream equipment and processes. Together, these components contribute to the efficient and reliable operation of compressed air systems.&lt;br /&gt;&lt;br /&gt;요약하자면, &lt;u&gt;공기 압축기는 대기 공기를 압축하여 압축 공기를 생성하고, 이 압축 공기는 리시버 탱크에 저장됩니다. 건조기는 압축 공기에서 수분을 제거&lt;/u&gt;하여 품질을 보장하고 다운스트림 장비 및 프로세스에서 잠재적인 문제를 방지하는 데 사용됩니다. 이러한 구성 요소는 함께 압축 공기 시스템의 효율적이고 안정적인 작동에 기여합니다.&lt;/blockquote&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/유,공압 Hydraulic, Pneumatic</category>
      <category>air compressor</category>
      <category>Air Compressors:</category>
      <category>compressed air system</category>
      <category>received tank</category>
      <category>Receiver Tanks</category>
      <category>공기압축시스템</category>
      <category>리시브탱크</category>
      <category>압축공기시스템</category>
      <category>에어컴프레샤</category>
      <category>에어컴프레서</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/17</guid>
      <comments>https://jacksonrius.tistory.com/17#entry17comment</comments>
      <pubDate>Thu, 7 Sep 2023 01:34:29 +0900</pubDate>
    </item>
    <item>
      <title>What is Recloser? 리클로져(자동 재폐로 파단기)</title>
      <link>https://jacksonrius.tistory.com/15</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;500&quot; data-origin-height=&quot;500&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bT6uHi/btssgpSJmzy/9EvL9iEOAB0kIzsKITMlIk/img.jpg&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bT6uHi/btssgpSJmzy/9EvL9iEOAB0kIzsKITMlIk/img.jpg&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bT6uHi/btssgpSJmzy/9EvL9iEOAB0kIzsKITMlIk/img.jpg&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbT6uHi%2FbtssgpSJmzy%2F9EvL9iEOAB0kIzsKITMlIk%2Fimg.jpg&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;398&quot; height=&quot;398&quot; data-origin-width=&quot;500&quot; data-origin-height=&quot;500&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;blockquote data-ke-style=&quot;style1&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;A recloser is a specialized type of circuit breaker used in electrical distribution systems to automatically detect and interrupt temporary faults that occur on power lines. Reclosers are designed to enhance the reliability of power distribution by automatically restoring power after momentary faults, such as tree branches touching power lines or lightning-induced disturbances, without the need for manual intervention.&lt;/span&gt;&lt;/blockquote&gt;
&lt;p style=&quot;text-align: center;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;리클로저는 전&lt;b&gt;력선에서 발생하는 일시적인 오류를 자동으로 감지하고 차단&lt;/b&gt;하기 위해 배전 시스템에 사용되는 특수 유형의 회로 차단기입니다. 리클로저는 나뭇가지가 송전선에 닿거나 낙뢰로 인한 교란 등 일시적인 장애가 발생하면 수동 개입 없이 &lt;b&gt;자동으로 전력을 복구하여 배전의 신뢰성을 높이도록 설계&lt;/b&gt;되었습니다.&lt;/span&gt;&lt;/p&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style5&quot; /&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;Here's how a recloser works and its key features:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;리클로저의 작동 방식과 주요 기능은 다음과 같습니다.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Key Features of Reclosers:&lt;/li&gt;
&lt;li&gt;리클로저 작동:&lt;/li&gt;
&lt;/ul&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Fault Detection:&lt;/b&gt; Reclosers continuously monitor the flow of current through power lines. When a temporary fault, such as a momentary short circuit, occurs on the line, the recloser's protective relays detect the abnormal current conditions.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Trip Operation:&lt;/b&gt; Upon detecting a fault, the recloser operates to open the circuit, interrupting the flow of current. This action isolates the faulted section from the rest of the distribution system, preventing further damage.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Automatic Reclosing:&lt;/b&gt; After a brief delay (typically a few seconds), the recloser automatically attempts to restore power by closing the circuit again. This is based on the assumption that the fault causing the interruption was temporary in nature (e.g., a tree branch falling on the line) and has cleared.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Multiple Reclosure Attempts:&lt;/b&gt; Reclosers are designed to make multiple reclosure attempts within a short timeframe (usually three attempts). If the fault persists after several reclosure attempts, the recloser will lock out and remain open until manually reset by a utility technician.&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;오류 감지:&lt;/b&gt; 리클로저는 전력선을 통한 전류 흐름을 지속적으로 모니터링합니다. 순간적인 단락과 같은 일시적인 결함이 선로에 발생하면 리클로저의 보호 계전기가 비정상적인 전류 상태를 감지합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;트립 동작(Trip Operation):&lt;/b&gt; 고장을 감지하면 리클로저가 동작하여 회로를 개방하고 전류의 흐름을 차단합니다. 이 조치는 결함이 있는 부분을 배전 시스템의 나머지 부분과 격리하여 추가 손상을 방지합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;자동 재폐로:&lt;/b&gt; 짧은 지연(일반적으로 몇 초) 후에 재폐로 장치는 회로를 다시 닫아 자동으로 전원 복원을 시도합니다. 이는 중단을 초래한 결함이 본질적으로 일시적(예: 선로에 나무 가지가 떨어지는 경우)이었고 해결되었다는 가정을 기반으로 합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;다중 재폐쇄 시도:&lt;/b&gt; 리클로저는 짧은 시간 내에(보통 3회 시도) 여러 번 재폐쇄를 시도하도록 설계되었습니다. 여러 번의 재폐로 시도 후에도 결함이 지속되면 리클로저는 잠기고 유틸리티 기술자가 수동으로 재설정할 때까지 열린 상태를 유지합니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Key Features of Reclosers:&lt;/li&gt;
&lt;li&gt;리클로저의 주요 특징:&lt;/li&gt;
&lt;/ul&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Protection:&lt;/b&gt; Reclosers provide protection against temporary faults that might resolve on their own. They help prevent unnecessary outages by restoring power without requiring manual intervention.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Automatic Operation:&lt;/b&gt; Reclosers operate automatically based on preset settings and parameters. This reduces the need for personnel to physically visit the site for every fault occurrence.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Time Delays:&lt;/b&gt; Reclosers incorporate time delays between trips and reclosure attempts. These delays allow temporary&amp;nbsp;faults&amp;nbsp;to&amp;nbsp;clear&amp;nbsp;while&amp;nbsp;also&amp;nbsp;protecting against persistent or severe faults.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Remote Monitoring:&lt;/b&gt; Many reclosers are equipped with communication capabilities, allowing utility operators to remotely monitor their status and performance.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Adaptive Logic:&lt;/b&gt; Some advanced reclosers use adaptive logic to determine whether to attempt reclosure based on the specific characteristics of the fault and the historical behaviour of the line.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Reset and Lockout:&lt;/b&gt; If a fault persists after multiple reclosure attempts, the recloser will lock out to prevent continuous reclosure attempts. Utility personnel must manually reset the recloser after addressing the fault.&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;보호:&lt;/b&gt; 리클로저는 자체적으로 해결될 수 있는 일시적인 결함에 대한 보호 기능을 제공합니다. 수동 개입 없이 전원을 복원하여 불필요한 정전을 방지하는 데 도움이 됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;자동 작동:&lt;/b&gt; 리클로저는 사전 설정된 설정 및 매개변수에 따라 자동으로 작동합니다. 이렇게 하면 모든 오류가 발생할 때마다 직원이 현장을 물리적으로 방문할 필요성이 줄어듭니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;시간 지연:&lt;/b&gt; 리클로저에는 트립과 재폐쇄 시도 사이의 시간 지연이 포함됩니다. 이러한 지연을 통해 일시적인 오류를 제거하는 동시에 지속되거나 심각한 오류로부터 보호할 수도 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;원격 모니터링:&lt;/b&gt; 많은 리클로저에는 통신 기능이 장착되어 있어 유틸리티 운영자가 상태와 성능을 원격으로 모니터링할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;적응형 논리:&lt;/b&gt; 일부 고급 재폐로 장치는 적응형 논리를 사용하여 결함의 특정 특성과 라인의 과거 동작을 기반으로 재폐쇄를 시도할지 여부를 결정합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;재설정 및 잠금:&lt;/b&gt; 여러 번의 재폐로 시도 후에도 결함이 지속되면 리클로저는 지속적인 재폐로 시도를 방지하기 위해 잠깁니다. 유틸리티 직원은 결함을 해결한 후 리클로저를 수동으로 재설정해야 합니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style4&quot; /&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;Reclosers are particularly useful in overhead power distribution systems, such as those found in rural areas, as they help maintain a consistent power supply and reduce the duration of outages caused by transient faults. They play a significant role in improving the reliability and efficiency of electrical distribution networks.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;리클로저는 &lt;b&gt;전원 공급을 일관되게 유지하&lt;/b&gt;고 &lt;b&gt;일시적인 오류로 인한 정전 기간을 줄이는 데 도움&lt;/b&gt;이 되므로 &lt;u&gt;&lt;b&gt;농촌 지역과 같은 가공 배전 시스템에 특히 유용&lt;/b&gt;&lt;/u&gt;합니다. 이는 배전 네트워크의 신뢰성과 효율성을 향상시키는 데 중요한 역할을 합니다.&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/전기 Electrical engineering</category>
      <category>recloser</category>
      <category>리클로져</category>
      <category>자동개폐로장치</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/15</guid>
      <comments>https://jacksonrius.tistory.com/15#entry15comment</comments>
      <pubDate>Tue, 29 Aug 2023 04:27:49 +0900</pubDate>
    </item>
    <item>
      <title>What is MTTR, MTTF and MTBF? 란 무엇인가?</title>
      <link>https://jacksonrius.tistory.com/14</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;678&quot; data-origin-height=&quot;199&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/coC9C2/btsr61SagTX/vq5pvKIvt73NbsmuuNbnvK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/coC9C2/btsr61SagTX/vq5pvKIvt73NbsmuuNbnvK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/coC9C2/btsr61SagTX/vq5pvKIvt73NbsmuuNbnvK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FcoC9C2%2Fbtsr61SagTX%2Fvq5pvKIvt73NbsmuuNbnvK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;678&quot; height=&quot;199&quot; data-origin-width=&quot;678&quot; data-origin-height=&quot;199&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;blockquote data-ke-style=&quot;style1&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;MTTR, MTTF, and MTBF are three important &lt;u&gt;metrics &lt;/u&gt;used in &lt;u&gt;reliability&lt;/u&gt; and maintenance engineering to evaluate the performance and availability of systems or equipment. Each of these metrics focuses on different aspects of system reliability and downtime:&lt;/span&gt;&lt;/blockquote&gt;
&lt;p style=&quot;text-align: center;&quot; data-ke-size=&quot;size16&quot;&gt;MTTR, MTTF 및 MTBF는 시스템이나 장비의 성능과 가용성을 평가하기 위해 안정성 및 유지 관리 엔지니어링에 사용되는 세 가지 중요한 지표입니다. 이러한 각 지표는 시스템 안정성 및 가동 중지 시간의 다양한 측면에 중점을 둡니다.&lt;/p&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style2&quot; /&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;MTTR (Mean Time To Repair): MTTR stands for &quot;Mean Time To Repair.&quot; It represents the average time it takes to repair a system or equipment after a failure or breakdown. MTTR measures the downtime of a system due to repairs. A lower MTTR indicates that the system can &lt;u&gt;be restored to&lt;/u&gt; working condition more quickly after a failure, which can help reduce &lt;u&gt;productivity losses&lt;/u&gt; and improve overall system availability.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;MTTR(평균 수리 시간): MTTR은 &quot;평균 수리 시간&quot;을 나타냅니다. 고장이나 고장이 발생한 후 시스템이나 장비를 수리하는 데 걸리는 평균 시간을 나타냅니다. MTTR은 수리로 인한 시스템 가동 중지 시간을 측정합니다. MTTR이 낮다는 것은 시스템이 장애 발생 후 더 빨리 작동 상태로 복원될 수 있음을 의미하며, 이는 생산성 손실을 줄이고 전반적인 시스템 가용성을 향상시키는 데 도움이 될 수 있습니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;Mathematically, MTTR is calculated by summing up the repair times for all instances of failure and then dividing by the total number of failures:&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;수학적으로 MTTR은 모든 오류 인스턴스에 대한 수리 시간을 합산한 다음 총 오류 수로 나누어 계산됩니다.&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;MTTR = Total Repair Time / Number of Failures&lt;/li&gt;
&lt;li&gt;MTTR = 총 수리 시간 / 고장 횟수&lt;/li&gt;
&lt;/ul&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style3&quot; /&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt;MTTF (Mean Time To Failure): MTTF stands for &quot;Mean Time To Failure.&quot; It represents the average time it takes for a system or equipment to fail. MTTF is commonly used for items that are replaced or discarded after a single failure, rather than repaired. MTTF is an important metric for assessing the reliability of products and components.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;MTTF(평균 고장 시간): MTTF는 &quot;평균 고장 시간&quot;을 나타냅니다. 시스템이나 장비가 고장나는 데 걸리는 평균 시간을 나타냅니다. MTTF는 일반적으로 수리보다는 단일 고장 후 교체 또는 폐기되는 품목에 사용됩니다. MTTF는 제품과 부품의 신뢰성을 평가하는 중요한 지표입니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;Mathematically, MTTF is calculated by summing up the time-to-failure for all instances and then dividing by the total number of failures:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;수학적으로 MTTF는 모든 인스턴스의 실패 시간을 합산한 다음 총 실패 수로 나누어 계산됩니다.&lt;/span&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;MTTF = Total Time to Failure / Number of Failures&lt;/li&gt;
&lt;li&gt;MTTF = 총 실패 시간 / 실패 횟수&lt;/li&gt;
&lt;/ul&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style1&quot; /&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot;&gt;MTBF (Mean Time Between Failures): MTBF stands for &quot;Mean Time Between Failures.&quot; It represents the average time that elapses between one failure of a system or equipment and the next failure. MTBF is a measure of the reliability of a system &amp;ndash; a higher MTBF suggests that the system is more reliable and less prone to failures.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;MTBF(평균 고장 간격): MTBF는 &quot;평균 고장 간격&quot;을 나타냅니다. 이는 시스템이나 장비의 한 오류와 다음 오류 사이의 평균 시간을 나타냅니다. MTBF는 시스템의 신뢰성을 측정한 것입니다. MTBF가 높을수록 시스템의 신뢰성이 높아지고 오류 발생 가능성이 낮다는 것을 의미합니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;Mathematically, MTBF is calculated by summing up the operational time (time between failures) and then dividing by the number of failures:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;수학적으로 MTBF는 작동 시간(고장 간 시간)을 합산한 다음 고장 횟수로 나누어 계산합니다.&lt;/span&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;MTBF = Total Operational Time / Number of Failures&lt;/li&gt;
&lt;li&gt;MTBF = 총 작동 시간 / 장애 횟수&lt;/li&gt;
&lt;/ul&gt;
&lt;blockquote data-ke-style=&quot;style3&quot;&gt;It's important to note that these metrics provide different insights into system reliability and downtime. MTTR focuses on repair time, MTTF focuses on the time until a failure occurs, and MTBF focuses on the time between consecutive failures. The choice of which metric to use depends on the specific context and the goals of the reliability assessment.&lt;br /&gt;&lt;br /&gt;이러한 지표는 시스템 안정성과 가동 중지 시간에 대한 다양한 통찰력을 제공한다는 점에 유의하는 것이 중요합니다. MTTR은 &lt;b&gt;수리 시간에 초점&lt;/b&gt;을 맞추고, MTTF는 &lt;b&gt;고장이 발생할 때까지의 시간에 초점&lt;/b&gt;을 맞추고, MTBF는 &lt;b&gt;연속 고장 사이의 시간에 초점&lt;/b&gt;을 맞춥니다. 사용할 측정항목의 선택은 신뢰성 평가의 특정 상황과 목표에 따라 달라집니다.&lt;/blockquote&gt;</description>
      <category>설비보전 Facility maintenance/보전 용어</category>
      <category>MTBF</category>
      <category>MTTF</category>
      <category>MTTR</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/14</guid>
      <comments>https://jacksonrius.tistory.com/14#entry14comment</comments>
      <pubDate>Fri, 25 Aug 2023 03:01:53 +0900</pubDate>
    </item>
    <item>
      <title>퓨즈, 퓨즈홀더 What is a fuse and fuse holder?</title>
      <link>https://jacksonrius.tistory.com/13</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;800&quot; data-origin-height=&quot;1067&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/efY8FN/btsrR3J4ilD/6PtWTp6gDqA1jKzKkqtRPK/img.jpg&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/efY8FN/btsrR3J4ilD/6PtWTp6gDqA1jKzKkqtRPK/img.jpg&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/efY8FN/btsrR3J4ilD/6PtWTp6gDqA1jKzKkqtRPK/img.jpg&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FefY8FN%2FbtsrR3J4ilD%2F6PtWTp6gDqA1jKzKkqtRPK%2Fimg.jpg&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;398&quot; height=&quot;531&quot; data-origin-width=&quot;800&quot; data-origin-height=&quot;1067&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p data-ke-size=&quot;size18&quot;&gt;&lt;b&gt;1. Fuse&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;Fuses are important components of electrical circuits that serve the primary role of protecting the circuit, equipment, and personnel from the potential dangers of overcurrent conditions, such as short circuits and overloads. Fuses work by interrupting the flow of electrical current when it exceeds a safe level, preventing damage to the circuit and associated components. Here's a detailed explanation of their role and how they work:&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;퓨즈는 단락 및 과부하와 같은 과전류 조건의 잠재적 위험으로부터 회로, 장비 및 인력을 보호하는 주요 역할을 하는 전기 회로의 중요한 구성 요소입니다. 퓨즈는 전류가 안전한 수준을 초과할 때 전류 흐름을 차단하여 작동하여 회로 및 관련 구성 요소의 손상을 방지합니다. 이들의 역할과 작동 방식에 대한 자세한 설명은 다음과 같습니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;Role of Fuses:&lt;/b&gt;&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Overcurrent Protection:&lt;/b&gt; Fuses are designed to protect electrical circuits and equipment from excessive current. When an overcurrent situation occurs, such as a short circuit or overload, the current can rise to dangerous levels that could damage wires, equipment, or even cause fires. Fuses act as a safety barrier to prevent these situations from causing harm.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Circuit Isolation:&lt;/b&gt; Fuses play a crucial role in isolating faulty sections of a circuit. When a fault occurs, such as a short circuit, the fuse quickly blows, interrupting the current flow and isolating the faulted section. This prevents the fault from spreading to other parts of the circuit.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Fire Prevention:&lt;/b&gt; Overcurrents can lead to excessive heat generation, which can cause insulation materials to melt or ignite. By interrupting the flow of current in a timely manner, fuses help prevent overheating and the potential for fires.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Protection of Equipment:&lt;/b&gt; Fuses safeguard sensitive and expensive equipment by preventing excessive current from damaging components. This is especially important in electronic devices where even small overcurrents can cause irreparable damage.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Personnel Safety:&lt;/b&gt; Fuses contribute to the safety of individuals working with or near electrical systems. By preventing overcurrents that could cause electrical shock or fire, fuses protect personnel from potential hazards.&lt;/li&gt;
&lt;/ol&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;퓨즈의 역할:&lt;/b&gt;&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;과전류 보호:&lt;/b&gt; 퓨즈는 과도한 전류로부터 전기 회로와 장비를 보호하도록 설계되었습니다. 단락이나 과부하와 같은 과전류 상황이 발생하면 전류가 전선, 장비를 손상시키거나 심지어 화재를 일으킬 수 있는 위험한 수준까지 상승할 수 있습니다. 퓨즈는 이러한 상황이 해를 끼치는 것을 방지하는 안전 장벽 역할을 합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;회로 절연:&lt;/b&gt; 퓨즈는 회로의 결함이 있는 부분을 절연하는 데 중요한 역할을 합니다. 단락 등의 고장이 발생하면 퓨즈가 빠르게 끊어져 전류 흐름을 차단하고 고장난 부분을 격리합니다. 이렇게 하면 결함이 회로의 다른 부분으로 퍼지는 것을 방지할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;화재 예방:&lt;/b&gt; 과전류는 과도한 열 발생으로 이어져 단열재가 녹거나 발화될 수 있습니다. 적시에 전류 흐름을 차단함으로써 퓨즈는 과열 및 화재 가능성을 방지하는 데 도움이 됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;장비 보호:&lt;/b&gt; 퓨즈는 과도한 전류로 인해 구성 요소가 손상되는 것을 방지하여 민감하고 값비싼 장비를 보호합니다. 이는 작은 과전류라도 복구할 수 없는 손상을 일으킬 수 있는 전자 장치에서 특히 중요합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;직원 안전:&lt;/b&gt; 퓨즈는 전기 시스템을 사용하거나 근처에서 작업하는 개인의 안전에 기여합니다. 감전이나 화재를 일으킬 수 있는 과전류를 방지함으로써 퓨즈는 잠재적인 위험으로부터 인력을 보호합니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;How Fuses Work:&lt;/b&gt; Fuses work based on the principle of electrical resistance and the thermal effects of current flow. Here's a step-by-step breakdown of how fuses operate:&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;퓨즈 작동 원리:&lt;/b&gt; 퓨즈는 전기 저항 원리와 전류 흐름의 열 효과를 기반으로 작동합니다. 퓨즈 작동 방식에 대한 단계별 분석은 다음과 같습니다.&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Fuse Element:&lt;/b&gt; Fuses consist of a metal conductor (fuse element) with a low melting point. This element is the weakest link in the circuit and is chosen based on the current rating of the fuse.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Normal Operation:&lt;/b&gt; Under normal operating conditions, the current flowing through the circuit heats up the fuse element to a certain extent, but not to the point of melting. The fuse remains intact, allowing current to flow through the circuit.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Overcurrent Condition:&lt;/b&gt; When an overcurrent condition occurs, such as a short circuit or overload, the current flowing through the circuit increases significantly.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Heating Effect:&lt;/b&gt; The increased current passing through the fuse element leads to a higher rate of heating. The element heats up rapidly due to its resistance.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Melting of Fuse Element:&lt;/b&gt; As the fuse element continues to heat up, it eventually reaches its melting point. When this happens, the fuse element melts, breaking the circuit and creating an open gap in the conductor.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Circuit Interruption:&lt;/b&gt; The melting of the fuse element results in an open circuit. This interruption in the current flow isolates the faulted section of the circuit and prevents excessive current from causing damage.&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;퓨즈 요소:&lt;/b&gt; 퓨즈는 융점이 낮은 금속 도체(퓨즈 요소)로 구성됩니다. 이 요소는 회로에서 가장 약한 링크이며 퓨즈의 전류 정격을 기준으로 선택됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;정상 작동:&lt;/b&gt; 정상 작동 조건에서 회로를 통해 흐르는 전류는 퓨즈 요소를 어느 정도 가열하지만 녹는 지점까지는 가열하지 않습니다. 퓨즈는 그대로 유지되어 전류가 회로를 통해 흐를 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;과전류 상태:&lt;/b&gt; 단락이나 과부하와 같은 과전류 상태가 발생하면 회로를 통해 흐르는 전류가 크게 증가합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;가열 효과:&lt;/b&gt; 퓨즈 요소를 통과하는 전류가 증가하면 가열 속도가 빨라집니다. 저항으로 인해 요소가 빠르게 가열됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;퓨즈 요소의 용융:&lt;/b&gt; 퓨즈 요소가 계속 가열됨에 따라 결국 녹는점에 도달합니다. 이런 일이 발생하면 퓨즈 요소가 녹아 회로가 파손되고 도체에 틈이 생깁니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;회로 중단:&lt;/b&gt; 퓨즈 요소가 녹아 개방 회로가 발생합니다. 전류 흐름의 이러한 중단은 회로의 결함이 있는 부분을 격리하고 과도한 전류가 손상을 일으키는 것을 방지합니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;It's important to note that fuses are generally designed as one-time-use devices. Once a fuse blows and interrupts the circuit, it needs to be replaced with a new fuse to restore normal operation. The choice of fuse rating (current capacity) is crucial, as selecting a fuse with too high a rating may not provide adequate protection, while selecting one with too low a rating may cause nuisance trips. Proper fuse selection ensures that the fuse reacts appropriately to overcurrent conditions while maintaining the integrity of the circuit and the safety of the system.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;퓨즈는 일반적으로 일회용 장치로 설계된다는 점에 유의하는 것이 중요합니다. 퓨즈가 끊어져 회로가 중단되면 정상적인 작동을 복원하기 위해 새 퓨즈로 교체해야 합니다. 정격이 너무 높은 퓨즈를 선택하면 적절한 보호 기능을 제공하지 못할 수 있고, 정격이 너무 낮은 퓨즈를 선택하면 불필요한 트립이 발생할 수 있으므로 퓨즈 정격(전류 용량)의 선택이 중요합니다. 적절한 퓨즈를 선택하면 퓨즈가 과전류 조건에 적절하게 반응하는 동시에 회로의 무결성과 시스템의 안전성을 유지할 수 있습니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size18&quot;&gt;&lt;b&gt;2. Fuse holder&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;A fuse holder, also known as a fuse socket or fuse base, is a device designed to securely hold and connect a fuse in an electrical circuit. It provides a safe and reliable way to insert, secure, and replace fuses as needed. Fuse holders are commonly used in various applications to protect circuits and equipment from overcurrent conditions, such as short circuits and overloads.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;Here are the key features and functions of a fuse holder&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;퓨즈 소켓 또는 퓨즈 베이스라고도 알려진 퓨즈 홀더는 전기 회로에서 퓨즈를 단단히 고정하고 연결하도록 설계된 장치입니다. 필요에 따라 퓨즈를 삽입, 고정 및 교체하는 안전하고 안정적인 방법을 제공합니다. 퓨즈 홀더는 일반적으로 단락 및 과부하와 같은 과전류 조건으로부터 회로 및 장비를 보호하기 위해 다양한 응용 분야에 사용됩니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;퓨즈 홀더의 주요 특징과 기능은 다음과 같습니다.&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Secure Mounting:&lt;/b&gt; Fuse holders are designed to securely hold a fuse in place within an electrical circuit. They provide a housing that prevents the fuse from moving or coming into contact with other components.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Electrical Connection:&lt;/b&gt; Fuse holders include terminals or contacts that establish a reliable electrical connection with the fuse. These contacts ensure that the electrical current can flow through the fuse and the circuit as intended.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Fuse Replacement:&lt;/b&gt; Fuse holders allow for easy replacement of fuses. When a fuse blows due to an overcurrent condition, it can be removed from the holder and replaced with a new fuse of the appropriate rating. This allows for quick restoration of the circuit without needing to replace the entire holder.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Fuse Protection:&lt;/b&gt; The design of a fuse holder helps protect the fuse from environmental factors like dust, moisture, and mechanical damage. This is especially important in outdoor or industrial settings where the electrical system might be exposed to harsh conditions.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Fuse Rating Compatibility:&lt;/b&gt; Fuse holders are designed to accommodate fuses of specific sizes and current ratings. It's essential to choose a fuse holder that matches the physical dimensions and the current capacity of the fuse being used.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Visual Indication:&lt;/b&gt; Some fuse holders feature transparent covers or windows that allow users to visually inspect the fuse's status without removing it from the holder. This can help identify blown fuses quickly.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Variety of Designs:&lt;/b&gt; Fuse holders come in various shapes, sizes, and configurations to suit different applications. They can be designed for panel mount, PCB mount, inline installation, and other installation methods.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Safety Considerations:&lt;/b&gt; Fuse holders often incorporate safety features to prevent accidental contact with live parts. For instance, some designs have finger-safe covers that shield users from direct contact with the live terminals.&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;안전한 장착:&lt;/b&gt; 퓨즈 홀더는 전기 회로 내에서 퓨즈를 제자리에 단단히 고정하도록 설계되었습니다. 퓨즈가 움직이거나 다른 구성 요소와 접촉하는 것을 방지하는 하우징을 제공합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;전기 연결:&lt;/b&gt; 퓨즈 홀더에는 퓨즈와 안정적인 전기 연결을 설정하는 단자 또는 접점이 포함되어 있습니다. 이러한 접점을 통해 전류가 의도한 대로 퓨즈와 회로를 통해 흐를 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;퓨즈 교체:&lt;/b&gt; 퓨즈 홀더를 사용하면 퓨즈를 쉽게 교체할 수 있습니다. 과전류 상태로 인해 퓨즈가 끊어지면 홀더에서 퓨즈를 제거하고 적절한 정격의 새 퓨즈로 교체할 수 있습니다. 이를 통해 홀더 전체를 교체할 필요 없이 회로를 빠르게 복원할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;퓨즈 보호:&lt;/b&gt; 퓨즈 홀더 설계는 먼지, 습기 및 기계적 손상과 같은 환경 요인으로부터 퓨즈를 보호하는 데 도움이 됩니다. 이는 전기 시스템이 가혹한 조건에 노출될 수 있는 실외 또는 산업 환경에서 특히 중요합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;퓨즈 등급 호환성:&lt;/b&gt; 퓨즈 홀더는 특정 크기와 전류 등급의 퓨즈를 수용하도록 설계되었습니다. 사용 중인 퓨즈의 물리적 크기와 현재 용량에 맞는 퓨즈 홀더를 선택하는 것이 중요합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;시각적 표시:&lt;/b&gt; 일부 퓨즈 홀더에는 사용자가 홀더에서 퓨즈를 제거하지 않고도 퓨즈 상태를 육안으로 검사할 수 있는 투명한 덮개나 창이 있습니다. 이렇게 하면 끊어진 퓨즈를 빠르게 식별하는 데 도움이 됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;다양한 디자인:&lt;/b&gt; 퓨즈 홀더는 다양한 용도에 맞게 다양한 모양, 크기 및 구성으로 제공됩니다. 패널 마운트, PCB 마운트, 인라인 설치 및 기타 설치 방법에 맞게 설계할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;안전 고려 사항:&lt;/b&gt; 퓨즈 홀더에는 충전 부품과의 우발적인 접촉을 방지하기 위한 안전 기능이 통합되어 있는 경우가 많습니다. 예를 들어, 일부 디자인에는 사용자가 라이브 터미널과 직접 접촉하지 못하도록 보호하는 손가락 보호 커버가 있습니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;Fuse holders are commonly used in electrical panels, control cabinets, industrial equipment, automotive applications, and many other scenarios where circuit protection is required. They play a crucial role in ensuring the proper functioning of electrical systems and providing a means to replace fuses conveniently when they blow due to overcurrent conditions. When selecting a fuse holder, it's important to consider factors such as the type of fuse being used, the current rating, the environmental conditions, and the installation requirements.&lt;/span&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;퓨즈&amp;nbsp;홀더는&amp;nbsp;전기&amp;nbsp;패널,&amp;nbsp;제어&amp;nbsp;캐비닛,&amp;nbsp;산업&amp;nbsp;장비,&amp;nbsp;자동차&amp;nbsp;애플리케이션&amp;nbsp;및&amp;nbsp;회로&amp;nbsp;보호가&amp;nbsp;필요한&amp;nbsp;기타&amp;nbsp;여러&amp;nbsp;시나리오에&amp;nbsp;일반적으로&amp;nbsp;사용됩니다.&amp;nbsp;이는&amp;nbsp;전기&amp;nbsp;시스템의&amp;nbsp;적절한&amp;nbsp;기능을&amp;nbsp;보장하고&amp;nbsp;과전류&amp;nbsp;조건으로&amp;nbsp;인해&amp;nbsp;퓨즈가&amp;nbsp;끊어졌을&amp;nbsp;때&amp;nbsp;퓨즈를&amp;nbsp;편리하게&amp;nbsp;교체할&amp;nbsp;수&amp;nbsp;있는&amp;nbsp;수단을&amp;nbsp;제공하는&amp;nbsp;데&amp;nbsp;중요한&amp;nbsp;역할을&amp;nbsp;합니다.&amp;nbsp;퓨즈&amp;nbsp;홀더를&amp;nbsp;선택할&amp;nbsp;때&amp;nbsp;사용되는&amp;nbsp;퓨즈&amp;nbsp;유형,&amp;nbsp;전류&amp;nbsp;정격,&amp;nbsp;환경&amp;nbsp;조건&amp;nbsp;및&amp;nbsp;설치&amp;nbsp;요구&amp;nbsp;사항과&amp;nbsp;같은&amp;nbsp;요소를&amp;nbsp;고려하는&amp;nbsp;것이&amp;nbsp;중요합니다.&lt;/span&gt;&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/전기 Electrical engineering</category>
      <category>fuseholder</category>
      <category>fusse</category>
      <category>퓨즈</category>
      <category>퓨즈홀더</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/13</guid>
      <comments>https://jacksonrius.tistory.com/13#entry13comment</comments>
      <pubDate>Wed, 23 Aug 2023 02:28:10 +0900</pubDate>
    </item>
    <item>
      <title>컷 아웃 스위치 란? What is COS(CUT OUT SWITCH)?</title>
      <link>https://jacksonrius.tistory.com/12</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;1208&quot; data-origin-height=&quot;811&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bGuknz/btsrR3Dju7d/P4OBVQLikq9sMs3lGEFtI1/img.jpg&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bGuknz/btsrR3Dju7d/P4OBVQLikq9sMs3lGEFtI1/img.jpg&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bGuknz/btsrR3Dju7d/P4OBVQLikq9sMs3lGEFtI1/img.jpg&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbGuknz%2FbtsrR3Dju7d%2FP4OBVQLikq9sMs3lGEFtI1%2Fimg.jpg&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;1208&quot; height=&quot;811&quot; data-origin-width=&quot;1208&quot; data-origin-height=&quot;811&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock widthContent&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;185&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bjeRMB/btsrNonxYh5/l23MHMlPT0Q10gkEj5wfqk/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bjeRMB/btsrNonxYh5/l23MHMlPT0Q10gkEj5wfqk/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bjeRMB/btsrNonxYh5/l23MHMlPT0Q10gkEj5wfqk/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbjeRMB%2FbtsrNonxYh5%2Fl23MHMlPT0Q10gkEj5wfqk%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;400&quot; height=&quot;185&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;185&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;A cutout switch, also known as a cutout fuse or dropout fuse, is a protective device used in electrical distribution systems to protect equipment, lines, and other components from overcurrents and faults. Its main role is to isolate a faulty section of a circuit or equipment by opening the circuit when an overcurrent or fault condition occurs. Here's how a cutout switch operates and its principle of operation:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;컷아웃 퓨즈 또는 드롭아웃 퓨즈라고도 하는 컷아웃 스위치는 &lt;b&gt;장비, 라인 및 기타 구성 요소를 과전류 및 오류로부터 보호하기 위해 배전 시스템에 사용되는 보호 장치입니다.&lt;/b&gt; 주요 역할은 &lt;b&gt;과전류나 고장 상태가 발생할 때 회로를 열어 회로나 장비의 고장난 부분을 격리&lt;/b&gt;하는 것입니다. 컷아웃 스위치의 작동 방식과 작동 원리는 다음과 같습니다.&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;Role of a Cutout Switch:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt; A cutout switch serves as a protective device in electrical distribution systems, particularly in overhead power lines. Its primary role is to prevent damage to the distribution line and associated equipment in case of a fault or overcurrent condition. It operates as a sacrificial element that interrupts the flow of current to protect more valuable equipment downstream, such as transformers, substations, and other sensitive components.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;컷아웃 스위치의 역할:&lt;/b&gt; 컷아웃 스위치는 배전 시스템, 특히 가공 전력선에서 보호 장치 역할을 합니다. 주요 역할은 오류 또는 &lt;b&gt;과전류 상태가 발생할 경우 배전선 및 관련 장비의 손상을 방지&lt;/b&gt;하는 것입니다. 이는 &lt;b&gt;변압기, 변전소 및 기타 민감한 구성 요소와 같은 더 귀중한 다운스트림 장비를 보호하기 위해 전류 흐름을 방해하는 희생 요소로 작동&lt;/b&gt;합니다.&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;Principle of Operation:&lt;/b&gt;&lt;span style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt; The cutout switch operates based on the principle of thermal and mechanical effects. Here's a step-by-step explanation of how it works:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;작동 원리:&lt;/b&gt; 컷아웃 스위치는 열적, 기계적 효과의 원리에 따라 작동합니다. 작동 방식에 대한 단계별 설명은 다음과 같습니다.&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Normal Operating Conditions:&lt;/b&gt; Under normal operating conditions, the cutout switch is closed, allowing current to flow through the distribution line without any interruption.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Overcurrent or Fault Condition:&lt;/b&gt; When an overcurrent or fault condition occurs in the distribution line, the current flowing through the cutout switch increases beyond its rated value. This could be due to a short circuit, overload, ground fault, or other faults.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Heating Effect:&lt;/b&gt; The increased current flowing through the cutout switch leads to a heating effect due to the resistance of the fuse element. The fuse element is designed to have a specific melting point.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Melting of Fuse Element:&lt;/b&gt; As the current continues to flow and the heating effect intensifies, the fuse element reaches its melting point. This causes the fuse element to melt and break, effectively opening the circuit.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Circuit Interruption:&lt;/b&gt; Once the fuse element melts, the circuit is interrupted, and the flow of current is stopped. This action isolates the faulty section of the circuit or equipment from the rest of the distribution system. By doing so, the cutout switch prevents the fault from spreading further and causing damage to downstream components.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Visible Indicator:&lt;/b&gt; Many cutout switches are designed with visible indicators, such as a flag or indicator pin, that visibly drop or move when the fuse element melts and the switch opens. This provides a clear visual indication to maintenance personnel that the switch has operated and needs attention.&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;정상 작동 조건:&lt;/b&gt; 정상 작동 조건에서는 컷아웃 스위치가 닫혀 전류가 중단 없이 배전선을 통해 흐를 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;과전류 또는 고장 상태:&lt;/b&gt; 배전선에 과전류 또는 고장 상태가 발생하면 차단 스위치를 통해 흐르는 전류가 정격 값 이상으로 증가합니다. 이는 단락, 과부하, 접지 오류 또는 기타 오류로 인해 발생할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;가열 효과:&lt;/b&gt; 컷아웃 스위치를 통해 흐르는 전류가 증가하면 퓨즈 요소의 저항으로 인해 가열 효과가 발생합니다. 퓨즈 요소는 특정 융점을 갖도록 설계되었습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;퓨즈 소자의 용융:&lt;/b&gt; 전류가 계속 흐르고 발열 효과가 강화됨에 따라 퓨즈 소자는 용융점에 도달합니다. 이로 인해 퓨즈 요소가 녹아 파손되어 회로가 효과적으로 개방됩니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;회로 차단:&lt;/b&gt; 퓨즈 요소가 녹으면 회로가 차단되고 전류 흐름이 중단됩니다. 이 조치는 회로 또는 장비의 결함이 있는 부분을 나머지 배전 시스템으로부터 격리합니다. 이렇게 함으로써 컷아웃 스위치는 결함이 더 확산되어 다운스트림 구성 요소가 손상되는 것을 방지합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;가시적 표시기:&lt;/b&gt; 많은 컷아웃 스위치는 퓨즈 요소가 녹아 스위치가 열리면 눈에 띄게 떨어지거나 움직이는 플래그 또는 표시기 핀과 같은 가시적 표시기로 설계됩니다. 이는 스위치가 작동했고 주의가 필요하다는 것을 유지보수 담당자에게 명확한 시각적 표시로 제공합니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;It's important to note that once a cutout switch operates and interrupts the circuit, it needs to be manually reset or replaced to restore normal operation. Cutout switches are designed to be easily replaceable, allowing for quick restoration of power after a fault has been cleared and the faulty section of the circuit has been repaired.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;컷아웃 스위치가 작동하여 회로를 중단하면 정상적인 작동을 복원하려면 수동으로 재설정하거나 교체해야 한다는 점에 유의하는 것이 중요합니다. 컷아웃 스위치는 쉽게 교체할 수 있도록 설계되어 오류가 해결되고 회로의 오류 부분이 수리된 후 전원을 신속하게 복구할 수 있습니다.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;In summary, a cutout switch plays a crucial role in protecting electrical distribution systems by opening the circuit in the event of overcurrent or fault conditions. Its operation is based on the heating and melting of a fuse element, which interrupts the flow of current and isolates the faulty section of the system from the rest of the distribution network.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;요약하면, 컷아웃 스위치는 과전류 또는 고장 상황에서 회로를 열어 배전 시스템을 보호하는 데 중요한 역할을 합니다. 그 작동은 퓨즈 요소의 가열 및 용해를 기반으로 하며, 이는 전류 흐름을 중단하고 시스템의 결함이 있는 부분을 나머지 배전 네트워크로부터 격리합니다.&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/전기 Electrical engineering</category>
      <category>Cos</category>
      <category>cutoutswitch</category>
      <category>컷아웃스위치</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/12</guid>
      <comments>https://jacksonrius.tistory.com/12#entry12comment</comments>
      <pubDate>Tue, 22 Aug 2023 23:13:01 +0900</pubDate>
    </item>
    <item>
      <title>전봇대 퓨즈 단락, 퓨즈 끊김 현상 원인 Why do fuses on power poles blow in industrial sites?</title>
      <link>https://jacksonrius.tistory.com/11</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;Fuses on power poles blow in industrial sites, and in general, due to various reasons related to electrical overloads, faults, and safety measures. Here are some common reasons why fuses on power poles might blow in industrial sites:&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;Overload&lt;/b&gt;: Industrial sites often require a significant amount of electrical power to operate machinery and equipment. If the demand for electricity exceeds the capacity of the electrical system, it can lead to an overload. This can cause the current flowing through the circuit to exceed the rated value of the fuse, resulting in the fuse blowing to protect the circuit from damage.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Short Circuits&lt;/b&gt;: A short circuit occurs when there is an unintended connection between two points in an electrical circuit with low resistance. This leads to a rapid increase in current flow, which can cause the fuse to blow. Short circuits can be caused by damaged wiring, faulty equipment, or other issues.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Ground Faults&lt;/b&gt;: A ground fault occurs when a live conductor comes into contact with a grounded object or surface. This can lead to an abnormal current path that can cause the fuse to blow. Ground faults pose significant safety risks, as they can result in electric shocks or fires.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Equipment Malfunctions&lt;/b&gt;: Industrial equipment can experience malfunctions that cause abnormal electrical behavior, such as sudden spikes in current. These spikes can lead to fuses blowing to prevent damage to the equipment and ensure the safety of the overall electrical system.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Aging Infrastructure&lt;/b&gt;: Over time, electrical infrastructure can degrade due to factors such as wear and tear, corrosion, and environmental conditions. This can increase the likelihood of electrical faults and overloads, leading to blown fuses.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Lightning Strikes&lt;/b&gt;: Industrial sites with outdoor electrical equipment are susceptible to lightning strikes. A lightning strike can introduce a massive surge of electrical energy into the system, overwhelming the protective mechanisms and causing fuses to blow.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Human Error&lt;/b&gt;: Mistakes during maintenance, repairs, or installation of new equipment can lead to incorrect wiring, improper connections, or other errors that result in electrical issues, including blown fuses.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Voltage Fluctuations&lt;/b&gt;: Unstable voltage levels, such as sudden increases or decreases in voltage, can impact the normal functioning of electrical systems. If the voltage exceeds the safe operating range, it can cause fuses to blow.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;Improper Load Distribution&lt;/b&gt;: In industrial settings with multiple circuits and loads, an improper distribution of loads can cause some circuits to be overloaded while others are underutilized. This imbalance can lead to blown fuses in overloaded circuits.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;Blown fuses are a safety feature designed to protect the electrical system, equipment, and personnel from potentially dangerous situations. When a fuse blows, it interrupts the circuit, preventing excessive current from flowing and potentially causing fires or other hazards. It's important for industrial sites to have proper maintenance and safety protocols in place to prevent blown fuses and address any underlying issues that may lead to electrical failures.&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;전봇대의 퓨즈는 산업 현장에서 일반적으로 전기 과부하, 고장 및 안전 조치와 관련된 다양한 원인으로 인해 끊어집니다. 다음은 산업 현장에서 전원 기둥의 퓨즈가 끊어질 수 있는 몇 가지 일반적인 이유입니다.&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;b&gt;과부하&lt;/b&gt; : 산업 현장은 기계 및 장비를 작동하기 위해 상당한 양의 전력이 필요한 경우가 많습니다. 전기 수요가 전기 시스템의 용량을 초과하면 과부하가 발생할 수 있습니다. 이로 인해 회로를 통해 흐르는 전류가 퓨즈의 정격 값을 초과하여 회로 손상을 방지하기 위해 퓨즈가 끊어질 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;단락&lt;/b&gt; : 저항이 낮은 전기 회로의 두 지점 사이에 의도하지 않은 연결이 있을 때 단락이 발생합니다. 이로 인해 전류 흐름이 급격히 증가하여 퓨즈가 끊어질 수 있습니다. 배선 손상, 장비 결함 또는 기타 문제로 인해 단락이 발생할 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;접지 오류&lt;/b&gt; : 접지 오류는 활선 도체가 접지된 물체 또는 표면과 접촉할 때 발생합니다. 이로 인해 퓨즈가 끊어질 수 있는 비정상적인 전류 경로가 발생할 수 있습니다. 접지 결함은 감전이나 화재로 이어질 수 있으므로 심각한 안전 위험을 초래합니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;장비 오작동&lt;/b&gt; : 산업 장비는 갑작스러운 전류 스파이크와 같은 비정상적인 전기 동작을 유발하는 오작동을 경험할 수 있습니다. 이러한 스파이크로 인해 장비 손상을 방지하고 전체 전기 시스템의 안전을 보장하기 위해 퓨즈가 끊어질 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;노후화된 인프라&lt;/b&gt; : 시간이 지남에 따라 전기 인프라는 마모, 부식 및 환경 조건과 같은 요인으로 인해 성능이 저하될 수 있습니다. 이로 인해 전기 결함 및 과부하가 발생할 가능성이 높아져 퓨즈가 끊어질 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;낙뢰&lt;/b&gt; : 야외 전기 설비가 있는 산업 현장은 낙뢰에 취약합니다. 낙뢰는 시스템에 막대한 전기 에너지 서지를 도입하여 보호 메커니즘을 압도하고 퓨즈를 끊을 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;인적 오류&lt;/b&gt; : 새 장비의 유지 관리, 수리 또는 설치 중 실수는 잘못된 배선, 부적절한 연결 또는 퓨즈 끊어짐을 포함하여 전기적 문제를 초래하는 기타 오류로 이어질 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;전압 변동&lt;/b&gt; : 전압의 급격한 증가 또는 감소와 같은 불안정한 전압 수준은 전기 시스템의 정상적인 기능에 영향을 미칠 수 있습니다. 전압이 안전 작동 범위를 초과하면 퓨즈가 끊어질 수 있습니다.&lt;/li&gt;
&lt;li&gt;&lt;b&gt;부적절한 부하 분배&lt;/b&gt; : 여러 회로와 부하가 있는 산업 환경에서 부적절하게 부하를 분배하면 일부 회로에 과부하가 걸리고 다른 회로는 충분히 활용되지 않을 수 있습니다. 이러한 불균형으로 인해 과부하 회로에서 퓨즈가 끊어질 수 있습니다.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;끊어진 퓨즈는 잠재적으로 위험한 상황으로부터 전기 시스템, 장비 및 인력을 보호하도록 설계된 안전 기능입니다. 퓨즈가 끊어지면 회로를 차단하여 과도한 전류가 흐르는 것을 방지하고 화재나 기타 위험을 유발할 수 있습니다. 산업 현장에서는 퓨즈 끊어짐을 방지하고 전기 고장으로 이어질 수 있는 근본적인 문제를 해결하기 위해 적절한 유지 관리 및 안전 프로토콜을 마련하는 것이 중요합니다.&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/Fuse issue</category>
      <category>blown</category>
      <category>Fuse</category>
      <category>fuseblown</category>
      <category>fuseshort</category>
      <category>Short</category>
      <category>퓨즈</category>
      <category>퓨즈끊김</category>
      <category>퓨즈단락</category>
      <category>퓨즈쇼트</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/11</guid>
      <comments>https://jacksonrius.tistory.com/11#entry11comment</comments>
      <pubDate>Tue, 22 Aug 2023 05:04:06 +0900</pubDate>
    </item>
    <item>
      <title>전기용어 '슬립(Slip)' What is a 'Slip' in electrical engineering?</title>
      <link>https://jacksonrius.tistory.com/10</link>
      <description>&lt;blockquote data-ke-style=&quot;style1&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;In electrical engineering, a &quot;slip&quot; can refer to the difference between the synchronous speed of a rotating magnetic field and the actual speed of a motor or generator.&lt;/span&gt;&lt;/blockquote&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;text-align: left; font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;전기 공학에서 &quot;슬립&quot;은 &lt;b&gt;회전 자기장의 동기 속도와 모터 또는 발전기의 실제 속도 간의 차이&lt;/b&gt;를 의미할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style8&quot; /&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;In the context of motors, a &quot;slip&quot; refers to a term used in AC (alternating current) induction motors. AC induction motors are widely used in various applications, including industrial machinery, household appliances, and more. They work based on the principle of electromagnetic induction.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif; color: #333333; text-align: start;&quot;&gt;모터와 관련하여 &quot;슬립&quot;은 AC(교류) 유도 모터에서 사용되는 용어를 나타냅니다. AC 유도 전동기는 산업 기계, 가전 제품 등 다양한 응용 분야에 널리 사용됩니다. 그들은 전자기 유도의 원리에 따라 작동합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;When an AC induction motor is running, the speed of the rotating magnetic field generated by the stator winding is not always perfectly synchronized with the speed of the rotor (the rotating part of the motor). This speed difference between the magnetic field's rotation and the rotor's rotation is known as &quot;slip.&quot;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif; background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;AC 유도 모터가 작동 중일 때 고정자 권선에 의해 생성된 회전 자기장의 속도는 회전자(모터의 회전 부분)의 속도와 항상 완벽하게 동기화되지 않습니다. 자기장의 회전과 로터의 회전 사이의 이러한 속도 차이를 &quot;슬립&quot;이라고 합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Slip is usually expressed as a percentage of the motor's synchronous speed. The synchronous speed is the speed at which the rotating magnetic field would rotate if there were no slip. The formula to calculate slip is:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif; background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;슬립은 일반적으로 모터 동기 속도의 백분율로 표시됩니다. 동기 속도는 슬립이 없을 경우 회전 자기장이 회전하는 속도입니다. 슬립을 계산하는 공식은 다음과 같습니다.&lt;/span&gt;&lt;/p&gt;
&lt;ul style=&quot;list-style-type: disc;&quot; data-ke-list-type=&quot;disc&quot;&gt;
&lt;li&gt;Slip (%) = ((Synchronous Speed - Actual Speed) / Synchronous Speed) * 100&lt;/li&gt;
&lt;li&gt;슬립(%) = ((동기 속도 - 실제 속도) / 동기 속도) * 100&lt;/li&gt;
&lt;/ul&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style2&quot; /&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Slip is important in the operation of induction motors because it affects the motor's performance and efficiency. Here's how slip impacts the motor's behaviour:&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif; background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;슬립은 모터의 성능과 효율에 영향을 미치기 때문에 유도 전동기의 작동에 중요합니다. 슬립이 모터의 동작에 미치는 영향은 다음과 같습니다.&lt;/span&gt;&lt;/p&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Torque Production: The difference in speed between the rotating magnetic field and the rotor induces a voltage in the rotor windings. This voltage leads to current flow and the production of torque, which drives the motor's load. The amount of torque produced is proportional to the slip.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Efficiency: A certain amount of slip is necessary to generate torque and overcome inertia when the motor starts. However, excessive slip can lead to reduced efficiency and increased energy consumption.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Speed Control: Slip can also be used for speed control in some applications. By changing the frequency of the AC power supply, the synchronous speed of the motor can be adjusted, affecting the slip and, consequently, the motor's speed.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;Heating: The slip generates currents in the rotor windings, which can lead to heating of the rotor. Excessive heating can damage the motor over time, so slip needs to be properly managed.&lt;/span&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;ol style=&quot;list-style-type: decimal; background-color: #f7f7f8; color: #374151; text-align: start;&quot; data-ke-list-type=&quot;decimal&quot;&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;토크 생성 : 회전하는 자기장과 로터 사이의 속도 차이는 로터 권선에 전압을 유도합니다. 이 전압은 모터의 부하를 구동하는 전류 흐름과 토크 생성으로 이어집니다. 생성된 토크의 양은 슬립에 비례합니다.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;효율성 : 모터가 기동할 때 토크를 생성하고 관성을 극복하기 위해 일정량의 슬립이 필요합니다. 그러나 과도한 미끄러짐은 효율성 감소와 에너지 소비 증가로 이어질 수 있습니다.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;속도 제어 : 슬립은 일부 응용 분야에서 속도 제어에도 사용할 수 있습니다. AC 전원 공급 장치의 주파수를 변경하여 모터의 동기 속도를 조정하여 슬립과 결과적으로 모터 속도에 영향을 줄 수 있습니다.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;가열 : 슬립은 회전자 권선에 전류를 생성하여 회전자를 가열할 수 있습니다. 과도한 열은 시간이 지남에 따라 모터를 손상시킬 수 있으므로 슬립을 적절하게 관리해야 합니다.&lt;/span&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;hr contenteditable=&quot;false&quot; data-ke-type=&quot;horizontalRule&quot; data-ke-style=&quot;style5&quot; /&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif;&quot;&gt;In summary, slip is a critical parameter in AC induction motors that influences torque production, efficiency, speed control, and heating. It's essential for motor designers, engineers, and operators to consider when designing, operating, and maintaining induction motor systems.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;background-color: #f7f7f8; color: #374151; text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: AppleSDGothicNeo-Regular, 'Malgun Gothic', '맑은 고딕', dotum, 돋움, sans-serif; background-color: #f7f7f8; color: #374151; text-align: start;&quot;&gt;요약하면 슬립은 토크 생성, 효율성, 속도 제어 및 가열에 영향을 미치는 AC 유도 모터의 중요한 매개변수입니다. 모터 설계자, 엔지니어 및 운영자가 유도 전동기 시스템을 설계, 작동 및 유지 관리할 때 고려해야 할 필수 요소입니다.&lt;/span&gt;&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/전기 Electrical engineering</category>
      <category>electrical enginering</category>
      <category>Slip</category>
      <category>슬립</category>
      <category>전기슬립</category>
      <category>전기용어</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/10</guid>
      <comments>https://jacksonrius.tistory.com/10#entry10comment</comments>
      <pubDate>Tue, 22 Aug 2023 04:41:12 +0900</pubDate>
    </item>
    <item>
      <title>Recloser 자동 재페로 장치 설치(퓨즈 단락 주요원인 및 대안)</title>
      <link>https://jacksonrius.tistory.com/9</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;퓨즈 단락 3회 의 주된 원인으로 변압기와 차단기 교체는 정답이 아니라는 것이 crosby electric 측의 의견이다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;OVERLOADING이 걸리는 주된 원인은 설비나 메인 퓨즈에서 직접 전압 과부하가 걸리는 것이 퓨즈 단락의 주요 원인이라는 의견이다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;이에대한 2가지 대안을 제시하였다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. 전봇대 퓨즈의&amp;nbsp; CAPA 200A -&amp;gt; 400A&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. Recloser 설치&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. 1번의 경우 알라바마 파워 측 변압기의 용량이 320A이기 떄문에 이보다 높은 용량으로 퓨즈를 교체할 시 문제가 생길 수 있고 책임에 문제가 생길 수 있다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;따라서. 알라바마 파워 측 승인을 받지 못하였다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. Recloser 설치 시 피용 $100,000 으로 너무 높은 설치 비용때문에 보류되었다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;현재는 퓨즈 단락의 직접적인 원인을 해결할 수 있는 유일한 방법이라는 의견이다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;R/C : Recloser - 자동 재폐로 장치&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/Fuse issue</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/9</guid>
      <comments>https://jacksonrius.tistory.com/9#entry9comment</comments>
      <pubDate>Sat, 19 Aug 2023 22:56:02 +0900</pubDate>
    </item>
    <item>
      <title>Circuit breaker for transformer 차단기 교체</title>
      <link>https://jacksonrius.tistory.com/8</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;08.11.23 15:15 Fuse blown 이 후&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.12.23 오전, 오후 라인 작업&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.13.23 야간 라인 작업&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.14.23 오전, 오후, 야간 라인 작업&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.15.23 오후, 야간 작업 -&amp;gt; 오전, 오후 컴프레셔 문제로 인한 라인 가동 불가&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.16.23 오전, 오후 라인 작업 중&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;현재 5일 째 퓨즈 이상없음&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;조치된 점&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;P1 Panel 저전압으로 인해 P1에서 전압이 공급되는 케이블들을 모두 다른&amp;nbsp; PANEL로 연결하여 대체하였다. 이 경우 P1의 변압기의 문제를 주로 보고있다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;변압기의 차단기(in M2 Panel) 에서 저전압을 발견, 나머지 차단기들은 정상전압이었으며 M2 Panel에 공급되는 전압도 정상임을 발견하였다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;M2 PANEL의 전압이 정상인 경우 SWITCH GEAR의 차단기의 전압도 정상이며 이에 따라 MAIN FUSE CIRCUIT BREAKER의 전압도 정상적임을 예측하고있다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;문제는 저전압인 P1 변압기의 차단기의 전압이 역류하여 퓨즈에 영향이 되었을 가능성을 보고있다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;P1 변압기와 그 변압기의 차단기를 사용하고 있지 않은 상태에서 퓨즈 단선 현상이 없다면 변압기 혹은 변압기의 차단기의&amp;nbsp; 문제로 확정될 가능성이 있다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;그러나, 역류될 경우 차단기 -&amp;gt; SWITCH GEAR 차단기 -&amp;gt; MAIN FUSE&amp;nbsp; 차단기 -&amp;gt; 전봇대 FUSE 순으로 트립이 발생하지 않은 점은 아직 확인하지 못하였다.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;CROSBYELECTRIC과의 진행사항&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. Transfomer, Branch panel of trnsfomer 점검 및 수리 진행 취소&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. Replace the 100A Breaker of the transformer in M2 Panel.&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;3. Replace the 150A Breaker of Compressor 50HP in the Switch gear room.&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/Fuse issue</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/8</guid>
      <comments>https://jacksonrius.tistory.com/8#entry8comment</comments>
      <pubDate>Fri, 18 Aug 2023 00:59:37 +0900</pubDate>
    </item>
    <item>
      <title>De-Energized</title>
      <link>https://jacksonrius.tistory.com/6</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;현상&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;08.11.23&amp;nbsp; 15:15&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #666666; text-align: start;&quot;&gt;세번쨰 Fuse blown 발생&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;조치&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;16:30 ~ 00:00&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. Crosbyelectric에서 퓨즈 교체 수행&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. Line 정상화&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;원인(추측)&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. 천둥 번개 날씨의 영향&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. P1 Transformer의 저전압 현상 발견 및 차단기 ON시 스파크 현상 발견&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;결과&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. 공장 내부 전등 시스템에 전압공급 이상 발견 -&amp;gt; Contactor(자동 소등 타이머) 내부 열화 발견&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. 100HP Compressor trip 발생&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;추가조치&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. Contactor(자동 소등 타이머) 우회&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. P1 Transfor 차단기 off&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;3. Elevator 차단기 off&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;4. 100HP Compressor 정상화&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;재발방지대책&lt;/b&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;1. DE-ENERGIZED 수행계획 수립 -&amp;gt; Transfomer 정상화 및 퓨즈단선 원인 발견 대책&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;2. 퓨즈 스페어 3개 확보&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;4. 전봇대 퓨즈 CAPA 200A -&amp;gt; 400A 향상계획 수립&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;i&gt;&lt;b&gt;DE-ENERGIZED&lt;/b&gt;&lt;/i&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;작업일자: 08.18.23&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;Objectives&lt;/b&gt;&amp;nbsp; &lt;/span&gt;수행목표&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;1. Preform De-Energized testing on Switchgear and Transformer.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;배전반 및 변압기에서 전원 차단 테스트를 수행합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;2. Provide a complete report of our findings, both written and electronic.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;우리가 발견한 내용에 대한 완전한 보고서를 서면 및 전자 형식으로 제공합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;3. Preform Predictive and proactive services such as making minor repairs and cleaning.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;사소한&amp;nbsp;수리&amp;nbsp;및&amp;nbsp;청소와&amp;nbsp;같은&amp;nbsp;예측적이고&amp;nbsp;능동적인&amp;nbsp;서비스를&amp;nbsp;수행합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;4. Furnish documentation of services before and after pictures of the equipment.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;장비&amp;nbsp;사진&amp;nbsp;전후의&amp;nbsp;서비스&amp;nbsp;문서를&amp;nbsp;제공합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;SCOPE OF WORK&lt;/b&gt;&amp;nbsp; 작업 범위&lt;/span&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000;&quot;&gt;1. 8 Switchgear - Vertical Section&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000;&quot;&gt;2. 1 &lt;span style=&quot;color: #000000;&quot;&gt;Transformer Dry - &amp;lt;=600V =&amp;gt; 250 kva&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;u&gt;&lt;b&gt;&lt;span style=&quot;color: #000000;&quot;&gt;&lt;span style=&quot;color: #000000;&quot;&gt;견적: &lt;span style=&quot;color: #000000;&quot;&gt;$9,885.00&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/u&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot; data-ke-size=&quot;size16&quot;&gt;DE-ENERGIZED는 아래 항목들을 수행합니다.&lt;/p&gt;
&lt;div&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;&lt;span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;b&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;u&gt;Visual and Mechanical Inspection:&lt;/u&gt; &lt;/span&gt;&lt;/b&gt;&lt;span&gt;Interior and exterior of all components will be inspected to ascertain and, if necessary, make certain adjustments to ensure that its performance remains within specified limits.&lt;span&gt;&amp;nbsp; &lt;/span&gt;We will also identify corrosion, rust and discolouration, leaks, safety hazards, applicable electric code violations, grounding, physical damage and the general condition of components.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;시각적&amp;nbsp;및&amp;nbsp;기계적&amp;nbsp;검사:&amp;nbsp;모든&amp;nbsp;구성&amp;nbsp;요소의&amp;nbsp;내부&amp;nbsp;및&amp;nbsp;외부를&amp;nbsp;검사하여&amp;nbsp;확인하고&amp;nbsp;필요한&amp;nbsp;경우&amp;nbsp;성능이&amp;nbsp;지정된&amp;nbsp;한도&amp;nbsp;내에서&amp;nbsp;유지되도록&amp;nbsp;조정합니다.&amp;nbsp;또한&amp;nbsp;부식,&amp;nbsp;녹&amp;nbsp;및&amp;nbsp;변색,&amp;nbsp;누출,&amp;nbsp;안전&amp;nbsp;위험,&amp;nbsp;적용&amp;nbsp;가능한&amp;nbsp;전기&amp;nbsp;규정&amp;nbsp;위반,&amp;nbsp;접지,&amp;nbsp;물리적&amp;nbsp;손상&amp;nbsp;및&amp;nbsp;구성&amp;nbsp;요소의&amp;nbsp;일반적인&amp;nbsp;상태를&amp;nbsp;식별합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;&lt;span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;b&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;u&gt;Insulation Resistance Service:&lt;/u&gt; &lt;/span&gt;&lt;/b&gt;&lt;span&gt;Measure and record the resistance of insulation under specified conditions set forth by manufacturer or NFPA Standard 70B.&lt;span&gt;&amp;nbsp; &lt;/span&gt;This service is designed to assure that your electrical system and components&amp;rsquo; insulation values are at an acceptable level, reducing the risk of explosions, fires and catastrophic breakdowns.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;절연&amp;nbsp;저항&amp;nbsp;서비스:&amp;nbsp;제조업체&amp;nbsp;또는&amp;nbsp;NFPA&amp;nbsp;표준&amp;nbsp;70B에서&amp;nbsp;지정한&amp;nbsp;특정&amp;nbsp;조건에서&amp;nbsp;절연&amp;nbsp;저항을&amp;nbsp;측정하고&amp;nbsp;기록합니다.&amp;nbsp;이&amp;nbsp;서비스는&amp;nbsp;전기&amp;nbsp;시스템&amp;nbsp;및&amp;nbsp;구성&amp;nbsp;요소의&amp;nbsp;절연&amp;nbsp;값이&amp;nbsp;허용&amp;nbsp;가능한&amp;nbsp;수준인지&amp;nbsp;확인하여&amp;nbsp;폭발,&amp;nbsp;화재&amp;nbsp;및&amp;nbsp;치명적인&amp;nbsp;고장의&amp;nbsp;위험을&amp;nbsp;줄이도록&amp;nbsp;설계되었습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;&lt;span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;b&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;u&gt;Contact Resistance Service:&lt;/u&gt; &lt;/span&gt;&lt;/b&gt;&lt;span&gt;Measure and record the resistances present between contact surfaces.&lt;span&gt;&amp;nbsp; &lt;/span&gt;This service addresses poor contact surfaces that would cause increased voltage drop, increased heat and reduced life expectancy, causing brown-outs, black-outs, explosions, fires and catastrophic failures.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;접촉&amp;nbsp;저항&amp;nbsp;서비스:&amp;nbsp;접촉&amp;nbsp;표면&amp;nbsp;사이에&amp;nbsp;존재하는&amp;nbsp;저항을&amp;nbsp;측정하고&amp;nbsp;기록합니다.&amp;nbsp;이&amp;nbsp;서비스는&amp;nbsp;전압&amp;nbsp;강하&amp;nbsp;증가,&amp;nbsp;열&amp;nbsp;증가&amp;nbsp;및&amp;nbsp;예상&amp;nbsp;수명&amp;nbsp;감소를&amp;nbsp;유발하여&amp;nbsp;정전,&amp;nbsp;정전,&amp;nbsp;폭발,&amp;nbsp;화재&amp;nbsp;및&amp;nbsp;치명적인&amp;nbsp;고장을&amp;nbsp;유발할&amp;nbsp;수&amp;nbsp;있는&amp;nbsp;불량&amp;nbsp;접촉&amp;nbsp;표면을&amp;nbsp;해결합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;&lt;span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;b&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;u&gt;Circuit Breaker Service (Low Voltage):&lt;/u&gt;&lt;/span&gt;&lt;/b&gt;&lt;span&gt; Measure, test, record and document findings regarding all applicable low voltage circuit breakers.&lt;span&gt;&amp;nbsp; &lt;/span&gt;The proper Service and inspection of your circuit breakers will reduce the risk of business interruption, fire and catastrophic failure.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;회로&amp;nbsp;차단기&amp;nbsp;서비스(저전압):&amp;nbsp;적용&amp;nbsp;가능한&amp;nbsp;모든&amp;nbsp;저전압&amp;nbsp;회로&amp;nbsp;차단기에&amp;nbsp;대한&amp;nbsp;결과를&amp;nbsp;측정,&amp;nbsp;테스트,&amp;nbsp;기록&amp;nbsp;및&amp;nbsp;문서화합니다.&amp;nbsp;회로&amp;nbsp;차단기에&amp;nbsp;대한&amp;nbsp;적절한&amp;nbsp;서비스&amp;nbsp;및&amp;nbsp;검사를&amp;nbsp;통해&amp;nbsp;업무&amp;nbsp;중단,&amp;nbsp;화재&amp;nbsp;및&amp;nbsp;치명적인&amp;nbsp;실패의&amp;nbsp;위험을&amp;nbsp;줄일&amp;nbsp;수&amp;nbsp;있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;b&gt;&lt;span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;b&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;u&gt;Transformer Service:&lt;/u&gt; &lt;/span&gt;&lt;/b&gt;&lt;span&gt;Measure, record and monitor all appropriate service and inspection to manufacturer&amp;rsquo;s recommendations and/or NFPA Standard 70B.&lt;span&gt;&amp;nbsp; &lt;/span&gt;This service and inspection is performed to reduce the risk of transformer failure, which could result in fire, and/or catastrophic failure.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;변압기&amp;nbsp;서비스:&amp;nbsp;제조업체의&amp;nbsp;권장&amp;nbsp;사항&amp;nbsp;및/또는&amp;nbsp;NFPA&amp;nbsp;표준&amp;nbsp;70B에&amp;nbsp;따라&amp;nbsp;모든&amp;nbsp;적절한&amp;nbsp;서비스&amp;nbsp;및&amp;nbsp;검사를&amp;nbsp;측정,&amp;nbsp;기록&amp;nbsp;및&amp;nbsp;모니터링합니다.&amp;nbsp;이&amp;nbsp;서비스&amp;nbsp;및&amp;nbsp;검사는&amp;nbsp;화재&amp;nbsp;및/또는&amp;nbsp;심각한&amp;nbsp;고장으로&amp;nbsp;이어질&amp;nbsp;수&amp;nbsp;있는&amp;nbsp;변압기&amp;nbsp;고장의&amp;nbsp;위험을&amp;nbsp;줄이기&amp;nbsp;위해&amp;nbsp;수행됩니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;&lt;u&gt;Equipment Nameplates:&lt;/u&gt; &lt;/b&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;Compare equipment nameplate data with drawings and specifications.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;장비&amp;nbsp;명판:&amp;nbsp;장비&amp;nbsp;명판&amp;nbsp;데이터를&amp;nbsp;도면&amp;nbsp;및&amp;nbsp;사양과&amp;nbsp;비교합니다.&lt;/span&gt;&lt;/p&gt;
&lt;/div&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Remove Covers:&lt;/u&gt; &lt;/b&gt;Remove and replace covers on all Electrical System Components, where applicable.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt; 커버&amp;nbsp;제거:&amp;nbsp;해당하는&amp;nbsp;경우&amp;nbsp;모든&amp;nbsp;전기&amp;nbsp;시스템&amp;nbsp;구성&amp;nbsp;요소의&amp;nbsp;커버를&amp;nbsp;제거하고&amp;nbsp;교체합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Inspection:&lt;/u&gt; &lt;/b&gt;Inspect physical, electrical, and mechanical condition.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt; 검사:&amp;nbsp;물리적,&amp;nbsp;전기적,&amp;nbsp;기계적&amp;nbsp;상태를&amp;nbsp;검사합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Check Tightness:&lt;/u&gt;&lt;/b&gt; Torque all connections and terminations to applicable specifications.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt; 견고성&amp;nbsp;확인:&amp;nbsp;모든&amp;nbsp;연결&amp;nbsp;및&amp;nbsp;종단을&amp;nbsp;해당&amp;nbsp;사양에&amp;nbsp;맞게&amp;nbsp;조입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Installation:&lt;/u&gt;&lt;/b&gt; Verify appropriate anchorage, required area clearances, physical damage, and correct alignment.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt; 설치:&amp;nbsp;적절한&amp;nbsp;앵커리지,&amp;nbsp;필요한&amp;nbsp;영역&amp;nbsp;간극,&amp;nbsp;물리적&amp;nbsp;손상&amp;nbsp;및&amp;nbsp;올바른&amp;nbsp;정렬을&amp;nbsp;확인하십시오.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Exercising:&lt;/u&gt; &lt;/b&gt;Exercise all active components (when applicable).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;운동:&amp;nbsp;모든&amp;nbsp;활성&amp;nbsp;구성&amp;nbsp;요소를&amp;nbsp;운동합니다(해당되는&amp;nbsp;경우).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Cleaning:&lt;/u&gt;&lt;/b&gt; Clean interior and exterior of equipment, including vacuuming or blowing out as required.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;청소:&amp;nbsp;필요에&amp;nbsp;따라&amp;nbsp;진공&amp;nbsp;청소기로&amp;nbsp;청소하거나&amp;nbsp;불어내는&amp;nbsp;것을&amp;nbsp;포함하여&amp;nbsp;장비의&amp;nbsp;내부와&amp;nbsp;외부를&amp;nbsp;청소합니다.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;&lt;b&gt;&lt;u&gt;Lubrication:&lt;/u&gt;&lt;/b&gt; Lubricate, as appropriate, to assure proper mechanical function(s).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span&gt;윤활:&amp;nbsp;적절한&amp;nbsp;기계적&amp;nbsp;기능을&amp;nbsp;보장하기&amp;nbsp;위해&amp;nbsp;적절하게&amp;nbsp;윤활하십시오.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;부가 진행 사항&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;1. 퓨즈 단선 재발 대비를 위한 FUSE 200A 3EA 확보 요청&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;2. 퓨즈 교체 200A -&amp;gt; 400A를 위한 Crosbyelectric 측 에서 Alabama power 측에 승인 요구 대기 -&amp;gt; 날짜 미정&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;3. 퓨즈 교체에 대한 견적 요구&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;4. Crosbyelectric PO 승인 대기&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;b&gt;현재 의심 사항&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;1. P1 Transfomer&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;2. Elevator&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;3. 변전실 항온항습&lt;/p&gt;</description>
      <category>설비보전 Facility maintenance/Fuse issue</category>
      <author>Jackson Lee</author>
      <guid isPermaLink="true">https://jacksonrius.tistory.com/6</guid>
      <comments>https://jacksonrius.tistory.com/6#entry6comment</comments>
      <pubDate>Wed, 16 Aug 2023 07:30:16 +0900</pubDate>
    </item>